CORD PROTECTOR Type | 330005-02

General Details

Status Active
Substitute Part Number
Variant Description n/a

Download Area / Documents

Where Part is Used

Item No. Qty Per Product Number Product Description Type Other Info Markets Product Status Last Date of Manuf. Diagram
62 1 D28700 CHOP SAW 1 item 73 changed to -01 and this spindle has flats on it so also need to change blade flanges to suit GB Discontinued 01/02/2011 go to diagram
62 1 D28700 CHOP SAW 1 B1 Discontinued 01/02/2011 go to diagram
62 1 D28700 CHOP SAW 1 XD Discontinued 01/02/2011 go to diagram
62 1 D28715 CHOP SAW 2 B5 Discontinued 17/11/2017 go to diagram
62 1 D28715 CHOP SAW 1 Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. GB Discontinued 29/03/2007 go to diagram
62 1 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) TDR REMOVAL (VI) - email 22-08-2013 may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch B5 - Discontinued via 2017 global NOD list = 17-11-17 GB Live go to diagram
62 1 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) B1 Discontinued 19/04/2018 go to diagram
17 1 DW359 7-1/4 CIRCULAR SAW -ASPAC 2 B4 Discontinued go to diagram
17 1 DW359 7-1/4 CIRCULAR SAW -ASPAC 1 B1 Discontinued go to diagram
17 1 DW368 CIRCULAR SAW 4 B1 Discontinued 13/01/2014 go to diagram
17 1 DW368 CIRCULAR SAW 3 BRUSH 230V WILL CHANGE TO N032830 CN0045257 - brush ring goes to N065058 KR - Discontinued 2013-06-30 on NOD B1 - Discotninued 2013-08-30 on NOD B1 Discontinued 13/01/2014 go to diagram
61 1 DW378G CIRCULAR SAW 1 NOD 10-085 (US market only) LMD 01-03-10 = SLD 01-03-15 (Replacement unit DWS535) B5 Discontinued 31/12/2010 go to diagram
17 1 DW389 CIRCULAR SAW 2 XD Discontinued go to diagram
17 1 DW389 CIRCULAR SAW 2 B4 Discontinued go to diagram
64 1 DW702 MITRE SAW 2 B1 Discontinued 01/12/2007 go to diagram
64 1 DW713 MITRE SAW 3 ZA MANUAL IN WINDCHILL IS TYPE 2 THEREFORE I HAVE ADDED THIS DW713-ZA - Discontinued via the 2017 global NOD review ZA Discontinued 01/01/2019 go to diagram
64 1 DW713 MITRE SAW 3 B1 Live go to diagram
64 1 DW713 MITRE SAW 1 GB Discontinued 17/03/2010 go to diagram
64 1 DW713 MITRE SAW 1 B1 Discontinued 17/03/2010 go to diagram
64 1 DW713 MITRE SAW 2 GB + LX - Obsoleted on NOD 252 NOD 413 B1 Discontinued 31/03/2011 go to diagram