HANDLE Type | 90562788

General Details

Status Active
Substitute Part Number
Variant Description n/a

Download Area / Documents

Where Part is Used

Item No. Qty Per Product Number Product Description Type Other Info Markets Product Status Last Date of Manuf. Diagram
18 1 DN49E SANDER 1 GB Discontinued 01/10/2010 go to diagram
18 1 DN49E SANDER 2 GB Live go to diagram
48 1 EMAX32 ROTARY MOWER 3 CHANGE TO TRANSMISSION, LOWER HANDLE AND SCREW TRANSMISSION FULLY COMPATIBLE WITH TYPES 1 & 2 items 51 and 38 changed pins from steel to plastic DTV EC1451501 NOD - FLD00081205 = EMAX32GSL2-CAFR02 (FOB unit) GB Discontinued 31/08/2016 go to diagram
48 1 EMAX32 ROTARY MOWER 1 120kg of tension needs to be applied to the belt. It acts as a brake for the blade <3seconds to stop. This tension can not be acheived by the customer so only the motor assembly is available. REA00072622 - EC1438441 WK11. The Rib on the switch housing does not hold the switch tightly enough. When the trigger is pulled the switch can slip causing intermittent power. Introduce a pad 90585848 to create a better fit.? MS2562 Items 8, 9, 10 and 13 had quality issues and all parts were redesigned for the type 2 unit. The BOM has been set up so that if any customer orders any of these parts the Type 2 switchbox is the sub. B1 Discontinued 01/08/2012 go to diagram
48 1 EMAX32 ROTARY MOWER 3 B1 Discontinued 27/03/2016 go to diagram
48 1 EMAX32 ROTARY MOWER 2 EMAX32GSL2 -B1 - GIFTBOX WITH 3.6v Li-ion SHRUBBER Yes. Type 2 SA switch box (as a whole item) can replace type 1 @ service EC1440462 - SWITCH BOX IMPROVEMENTPART NUMBERS GB Discontinued 31/05/2013 go to diagram
48 1 EMAX32 ROTARY MOWER 2 EMAX32GSL2 -B1 - GIFTBOX WITH 3.6v Li-ion SHRUBBER Yes. Type 2 SA switch box (as a whole item) can replace type 1 @ service EC1440462 - SWITCH BOX IMPROVEMENTPART NUMBERS B1 Discontinued 16/10/2013 go to diagram
48 1 EMAX32 ROTARY MOWER 1 120kg of tension needs to be applied to the belt. It acts as a brake for the blade <3seconds to stop. This tension can not be acheived by the customer so only the motor assembly is available. REA00072622 - EC1438441 WK11. The Rib on the switch housing does not hold the switch tightly enough. When the trigger is pulled the switch can slip causing intermittent power. Introduce a pad 90585848 to create a better fit.? MS2562 Items 8, 9, 10 and 13 had quality issues and all parts were redesigned for the type 2 unit. The BOM has been set up so that if any customer orders any of these parts the Type 2 switchbox is the sub. GB Discontinued 01/08/2012 go to diagram