VITE Type | 330022-18
Dettagli generali
| Stato | Active |
| Codice ricambio sostitutivo | |
| Descrizione variante | n/a |
Area download / Documenti
Dove è usato il ricambio
| Item No. | Qty Per | Product Number | Product Description | Tipo | Altre informazioni | Markets | Product Status | Ultima data di fabbricazione | Diagram |
|---|---|---|---|---|---|---|---|---|---|
| 106 | 1 | D26200 | Palm Router | 1 | USA RESPONSIBILITY | QS | Live |
|
|
| 106 | 1 | D26200K | ROUTER | 1 | COMPACT ROUTER FROM REYNOSA | QS | Live |
|
|
| 106 | 1 | D26203 | PLUNGE BASE COMPACT ROUTE | 1 | USA RESPONSIBILITY | QS | Live |
|
|
| 106 | 1 | D26203K | ROUTER | 1 | COMPACT ROUTER FROM REYNOSA - plunge base from suzhou | QS | Live |
|
|
| 106 | 2 | D26204K | Electronic Palm Router | 1 | USA RESPONSIBILITY | QS | Live |
|
|
| 44 | 2 | D28715 | CHOP SAW | 2 | A9 market deleted at request of douglas lim (Windchill = Development only) TDR REMOVAL (VI) - email 22-08-2013 may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch B5 - Discontinued via 2017 global NOD list = 17-11-17 | QS | Live |
|
|
| 44 | 2 | D28715 | CHOP SAW | 1 | Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. | QS | Discontinued | 29/03/2007 |
|
| 29 | 1 | DCW600 | ROUTER | 1 | ME&A and GEM region filters to be ticked on release Bare unit so no Battery or Chargers | QS | Live |
|
|
| 29 | 1 | DCW600 | ROUTER | 1 | ME&A and GEM region filters to be ticked on release Bare unit so no Battery or Chargers | QW | Live |
|
|
| 29 | 1 | DCW600N | 20V MAX XR CORDLESS COMPA | 1 | XJ | Live |
|
||
| 29 | 1 | DCW600N | 20V MAX XR CORDLESS COMPA | 2 | XJ | Live |
|
||
| 29 | 1 | DCW604 | ROUTER | 1 | CORDLESS VERSION OF D26203K RU TAKING EU VERSION | QS | Live |
|
|
| 72 | 1 | DCW604 | ROUTER | 1 | CORDLESS VERSION OF D26203K RU TAKING EU VERSION | QS | Live |
|
|
| 29 | 1 | DCW604 | ROUTER | 1 | QW | Live |
|
||
| 72 | 1 | DCW604 | ROUTER | 1 | QW | Live |
|
||
| 29 | 1 | DCW604N | CORDLESS ROUTER W/PLUNGE | 2 | XJ | Live |
|
||
| 72 | 1 | DCW604N | CORDLESS ROUTER W/PLUNGE | 2 | XJ | Live |
|
||
| 29 | 1 | DCW604N | CORDLESS ROUTER W/PLUNGE | 1 | XJ | Live |
|
||
| 72 | 1 | DCW604N | CORDLESS ROUTER W/PLUNGE | 1 | XJ | Live |
|
||
| 77 | 1 | DW713 | SEGA MITRE | 2 | GB + LX - Obsoleted on NOD 252 NOD 413 | QS | Discontinued | 31/03/2011 |
|