IDENTITY LABEL Type | 391325-00

General Details

Status Active
Substitute Part Number
Variant Description n/a

Download Area / Documents

Where Part is Used

Item No. Qty Per Product Number Product Description Type Other Info Markets Product Status Last Date of Manuf. Diagram
41 1 BD575E CUT SAW 1 GB Discontinued go to diagram
41 1 BD575E CUT SAW 2 GB Discontinued go to diagram
41 1 BD575E CUT SAW 3 GB Discontinued go to diagram
301 1 D27107 COMBINATION SAW 1 Only built as 230volt.....As from wk 1 2009 XC version made obsolete, suva guard no longer fitted. GB Discontinued 01/09/2009 go to diagram
93 1 D28700 CHOP SAW 1 B1 Discontinued 01/02/2011 go to diagram
93 1 D28700 CHOP SAW 1 XD Discontinued 01/02/2011 go to diagram
93 1 D28700 CHOP SAW 1 item 73 changed to -01 and this spindle has flats on it so also need to change blade flanges to suit GB Discontinued 01/02/2011 go to diagram
93 1 D28715 CHOP SAW 1 Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. GB Discontinued 29/03/2007 go to diagram
93 1 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) TDR REMOVAL (VI) - email 22-08-2013 may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding. Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch B5 - Discontinued via 2017 global NOD list = 17-11-17 GB Live go to diagram
93 1 D28715 CHOP SAW 2 B5 Discontinued 17/11/2017 go to diagram
93 1 D28715 CHOP SAW 2 A9 market deleted at request of douglas lim (Windchill = Development only) B1 Discontinued 19/04/2018 go to diagram
41 1 DW1201----E RADIAL ARM SAW 1 GB Discontinued go to diagram
41 1 DW1201----E RADIAL ARM SAW 2 GB Discontinued go to diagram
110 1 DW702 MITRE SAW 2 GB Discontinued 01/12/2007 go to diagram
110 1 DW702 MITRE SAW 1 GB Discontinued 01/05/2003 go to diagram
110 1 DW702 MITRE SAW 2 B1 Discontinued 01/12/2007 go to diagram
110 1 DW703 MITRE SAW 1 GB Discontinued 01/12/2002 go to diagram
110 1 DW703 MITRE SAW 2 TYPE 2 230 Volt only GB Discontinued 01/12/2003 go to diagram
110 1 DW703 MITRE SAW 3 GB Discontinued 01/12/2007 go to diagram
144 1 DW706 MITER SAW 1 GB Discontinued go to diagram