| 299 |
1 |
D27107 |
COMBINATION SAW |
1 |
Only built as 230volt.....As from wk 1 2009 XC version made obsolete, suva guard no longer fitted. |
GB |
Discontinued |
01/09/2009 |
|
| 57 |
1 |
D28700 |
CHOP SAW |
1 |
item 73 changed to -01 and this spindle has flats on it so also need to change blade flanges to suit |
GB |
Discontinued |
01/02/2011 |
|
| 57 |
1 |
D28700 |
CHOP SAW |
1 |
|
B1 |
Discontinued |
01/02/2011 |
|
| 57 |
1 |
D28700 |
CHOP SAW |
1 |
|
XD |
Discontinued |
01/02/2011 |
|
| 57 |
1 |
D28715 |
CHOP SAW |
2 |
A9 market deleted at request of douglas lim (Windchill = Development only) |
B1 |
Discontinued |
19/04/2018 |
|
| 57 |
1 |
D28715 |
CHOP SAW |
1 |
Type 2 unit may be removing soft start - field will only have 2 leads instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed
The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding.
Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two. |
GB |
Discontinued |
29/03/2007 |
|
| 57 |
1 |
D28715 |
CHOP SAW |
2 |
A9 market deleted at request of douglas lim (Windchill = Development only)
TDR REMOVAL (VI) - email 22-08-2013
may be removing soft start - New field will only have 2 longer leads wired directly into switch instead of 3 - no type change -They are hoping to begin production on the low voltage units on August 14th. The 230v units will be 3 months behind – testing hasn’t been completed
The soft start is accomplished by the field and TDR together. The TDR (Item #125) is a separate module/relay in the switch handle. So the TDR is removed and the field changes to one without the start winding.
Most likely sorted by date code and can add a note for the fields to identify one with 3 leads and the other with two.
For new field with 2 leads items 101,121 and 125 can be discarded and new field wired directly into switch
B5 - Discontinued via 2017 global NOD list = 17-11-17 |
GB |
Live |
|
|
| 57 |
1 |
D28715 |
CHOP SAW |
2 |
|
B5 |
Discontinued |
17/11/2017 |
|
| 23 |
1 |
SB2100 |
BLENDER |
1 |
|
GB |
Discontinued |
01/06/2017 |
|